User manual ver. 20220222
This document collects information on the safety, installation and use of the Auraton Libra H SET device.
Weekly, wireless temperature controller with heating or air conditioning controller (set) hotel version
The AURATON Libra H SET is a set consisting of a weekly, wireless AURATON Libra RH temperature controller ( hotel version ) and an AURATON Fornax heating or air conditioning controller. The set is designed to work with a gas or electric heating device.
Unique features of AURATON Libra RH
| STU | 9 temperature programs 3 independent temperatures: day, night, anti-freeze |
| \ | LCD display adapted to work in dimly lit rooms |
| [ | PWM operating mode |
| | } |
Heating or cooling operating mode |
| Hotel mode |
Unique features of AURATON Fornax
| ] | A unique algorithm for recording receiver operating parameters from the last 24 hours. The AURATON Fornax receiver is equipped with a unique algorithm for analyzing on/off cycles. The entire heating cycle from the last 24 hours is saved in the receiver's memory. In the event of a loss of communication with the AURATON Libra RH (transmitter), the Fornax receiver will automatically perform the memorized on/off cycle from the last 24 hours. This allows time to restore transmission (remove interference) or repair the AURATON Libra RH without significantly compromising thermal comfort in the controlled facility. |
| ^ | Cooperation with heating and air conditioning devices |
| _ | A dedicated switch makes servicing the heating device easier |
| ` | Controlling devices requiring live and voltage-free contacts. Relay switching is synchronized with the 230 V AC mains voltage so that the relay armature contacts always close and open at the zero crossing of the mains voltage. This prevents arcing and significantly increases the relay's durability. |
| { | Removable connection terminals |
Description of AURATON Libra RH
weekly, wireless temperature controller (transmitter), hotel version
The front of the AURATON Libra RH housing features a backlit LCD display, four function buttons and a temperature setting knob with an OK .

- LCD display
- Settings dial with integrated "OK"
- Mode selection button:
S – day mode (comfort),
T – night mode (economic) - Program selection button
- Button to set the time, day and week
- Temperature setting button
Display

- Day of the week (8 ) – Indicates what day of the week it is. Each day is assigned a number.
- Temperature – In normal operation mode, AURATON Libra RH displays the temperature of the room in which it is installed.
- Temperature Unit – Indicates whether the temperature is displayed in degrees Celsius (°C).
- Clock
The time is displayed in a 24-hour system. - Timeline:
Program progress indicator. This line is divided into 24 segments, each representing one hour. It shows how a given program is being executed. (See the "Timeline" section.) - Day mode indicator ( S )
Indicates that AURATON Libra RH is operating in day mode. (see chapter: "Temperature programming") - Night mode indicator ( T )
Indicates that the AURATON Libra RH is operating in night mode. (see chapter: "Temperature programming") - Anti-freeze mode indicator ( U )
Indicates that the AURATON Libra RH is operating in anti-freeze mode. (see section: "Anti-freeze mode") - Manual control indicator ( V )
Appears when you exit programmed operation. (see section: "Manual control mode") - Transmit symbol ( = )
Indicates communication with the receiver. - AURATON Libra RH On Indicator ( Y )
Segment informing about the device's operating status. Visible when the controlled device is turned on. - Program number
Indicates the number of the program currently running. (See chapters: "Factory programs" and "Weekly programming") - Battery drain (X)
This indicator appears when the battery voltage exceeds the minimum allowable level. The batteries should be replaced as soon as possible.
NOTE:
To maintain the programmed parameters, the battery replacement operation time should not exceed 30 seconds.
Choosing the right location for AURATON Libra RH

The proper operation of the AURATON Libra RH is significantly affected by its location. Siting it in a location lacking air circulation or exposed to direct sunlight may result in improper temperature control. The AURATON Libra RH should be installed on an interior wall (partition wall), in an environment with free air circulation. Avoid proximity to heat-emitting devices (TV, radiator, refrigerator) or locations exposed to direct sunlight. Proper operation may be impaired by proximity to doors, which expose the AURATON Libra RH to potential vibration.
Battery replacement
The battery compartment is located inside the AURATON Libra RH on the front of the case. To install the batteries, remove the AURATON Libra RH case as shown in the figure below:

We recommend alkaline batteries for powering AURATON controllers. Rechargeable batteries should not be used due to their low rated voltage.

- 1.5V AAA battery slot
Insert two 1.5V AAA batteries into the battery compartment, paying attention to the correct polarity of the batteries.
Mounting the AURATON Libra HR - weekly, wireless controller (transmitter) hotel version
To attach AURATON Libra RH to the wall:
- Remove the cover (as shown in the "Replacing the Battery" section)
- Drill two 6 mm diameter holes in the wall (mark the hole spacing using the rear part of the AURATON Libra RH housing).
- Insert the expansion bolts into the drilled holes.
- Screw the rear part of the AURATON Libra RH housing to the wall using the screws included in the kit.
- Put the casing on.
If you have a wooden wall, there is no need to use expansion bolts. Simply drill 2.7mm holes (instead of 6mm) and drive the screws directly into the wood.

- hole for the mounting screw
First launch of AURATON Libra RH
Once the batteries are properly inserted into the slots, the LCD will display all segments for one second, followed by the software version number.

After a moment, the AURATON Libra RH will automatically enter the time setting mode. A flashing element on the screen indicates it is currently in edit mode. Turn the knob left or right to set the desired time and confirm with the button. (.

By turning the knob left or right, we set the correct value in the minute segment and confirm it again with the button. (.

A flashing day of the week symbol appears in the upper left corner. Turn the knob left or right to set the desired day and confirm your selection with the button. (.

If no button is pressed for 60 seconds in the initial edit mode, the time will automatically default to 12:00 and Monday as the day of the week.
When programming any other functions, not pressing any button for 10 seconds is equivalent to using the button( .
Setting the clock and day of the week
To set the clock you need to:
-
Press the buttonm . The hour segment will start flashing on the display.

-
By turning the knob left or right, you set the desired hour and confirm with the button. (.
-
By turning the knob left or right, we set the correct value in the minute segment and confirm it again with the button. (.

-
A flashing day of the week symbol appears in the upper left corner. Turn the knob left or right to set the desired day and confirm your selection with the button. (.
NOTE:
You can also switch using the buttonm .Default program settings
- Monday - Friday:
the heating device operates at the day temperature ( S ) from 05:00 to 08:00 and from 15:00 to 23:00 - Saturday - Sunday:
the heating device operates at the day temperature ( S ) from 06:00 to 23:00 - default temperature settings:
S day temperature – 21.0°C
T night temperature – 19.0°C
U anti-freeze temperature – 7.0°C
Programming day and night temperatures
AURATON Libra RH allows you to programmatically set 2 types of temperature:
- Daytime temperature ( S ) – from 5 to 30°C
- Night temperature ( T ) – from 5 to 30°C
To set one of the above temperatures:- Press the buttonn .
-
The display will show the currently set temperature with the symbol:
S – day temperature;
T – night temperature.
- By turning the knob left or right we set the desired temperature value.
- Pressing the buttonn will switch the editing mode between day and night temperature ( S , T ).
- After setting the temperatures, confirm everything with the button. (.
NOTE:
The night temperature setting must be lower than the day temperature. It is not possible to set the night temperature higher than the day temperature.Introduction to programming
Timeline
The timeline on the LCD display is divided into 24 sections, each representing one hour of the day.
Black rectangles above the timeline indicate that the program has set the daytime temperature for that time; their absence indicates that the program has set the nighttime temperature.Example:

The figure above shows that from 6:00 a.m. to 11:00 p.m. AURATON Libra RH will control the heating device to maintain the room at day temperature ( S ). From 11:00 p.m. to 6:00 a.m. AURATON Libra RH will switch to night temperature ( T ).
Factory programs
To ensure the AURATON Libra RH knows when to switch to the day and night temperatures, you need to set a specific program for each day of the week. To do this, you can use one of three preset programs (from 0 to 2):
Program No. 0 – Anti-freeze. U
This factory program cannot be modified. Designed for setting the anti-freeze temperature all day long.Program No. 1 – Weekly
. Non-modifiable factory program. Sets the daily temperature from 5:00 to 8:00 and from 15:00 to 23:00.Program No. 2 – Weekend
. This factory program cannot be modified. It sets the daily temperature from 6:00 a.m. to 11:00 p.m.Program No. 3, 4,…, 8 – User
Programs No. 3 through No. 8 are user programs. They can be freely modified and adapted to your requirements.Programming
Weekly programming
Programming the AURATON Libra RH involves specifying the hours for a given day of the week during which the daytime temperature should be maintained. The nighttime temperature then applies.
Example AURATON Libra RH operating mode from Monday to Sunday. Outside of the time periods specified below, the AURATON Libra RH will maintain a lower nighttime temperature.
Day Daytime temperature Monday 5:00 – 8:00; 15:00 – 23:00 
Tuesday 5:00 – 8:00; 15:00 – 23:00 
Wednesday 5:00 – 8:00; 15:00 – 23:00 
Thursday 5:00 – 8:00; 15:00 – 23:00 
Friday 5:00 – 8:00; 15:00 – 23:00 
Saturday 8:00 – 23:00 
Sunday 8:00 – 23:00 
Program selection
To set up the program:
-
Press the buttonh . The program number segment will begin flashing.

-
Press the buttonm as many times as necessary to select the day of the week on which the program is to be carried out.

-
Press the button several timesh and select the desired program number. Programs 0-2 are factory-set, programs 3-8 can be modified.

- Confirm your selection with the button (.
- Repeat the procedure for the next days of the week.
Modifying a user program
To set up the program:
-
Press the buttonh . The program number segment will begin flashing.

-
Press the buttonm as many times as necessary to select the day of the week on which the program is to be carried out.

-
Press the button several timesh and select the desired program number. Programs 0-2 are factory-set, programs 3-8 can be modified.

-
All 24 black rectangles on the timeline will be lit, each representing one hour. A visible rectangle indicates that the daytime temperature is to be achieved at that hour. The absence of a rectangle above the timeline indicates that the nighttime temperature is scheduled.
The flashing rectangle indicates where on the timeline we are making changes.

-
Use the buttonr to select the day temperature (light rectangle) or night temperature (light rectangle). Then, use the knob to select the time interval for the given temperature.

-
By pressing the buttonr and selecting the time interval, we modify the entire program.

- We confirm everything with the button (
NOTE:
A modified program for a specific day can be selected and implemented also on another day of the week.Manual control
V
Option 1:
If for any reason you wish to interrupt the current program and extend the day or night temperature, you can do so manually, but for no longer than 24 hours. To do this:Hold the buttonr for 3 seconds. Then use the knob to select the number of manual operation hours (maximum 24 hours) and confirm the setting by pressing the button( .
The AURATON Libra RH will wait for you to set which of the two temperatures it should maintain (day or night). Changes can be made using the buttonr or the knob. Confirm your selection by pressing the button( .
Option 2:
If you would like to suspend the program, e.g., due to a prolonged party, and the AURATON Libra RH has already started lowering the temperature to the night temperature (the T ), and you would like to maintain the comfortable temperature until the end of the party, proceed as follows:
Press the buttonr the V and S symbols will appear on the display . The day temperature will then be maintained until the next temperature change implemented by the program.
To cancel this function, press the button( ; the symbol will disappearr from the display.Similarly, if the program is maintaining the day temperature, and you want to immediately enter the night temperature, then:
Press the buttonr V and T symbols will appear on the display . The night temperature will then be maintained until the next temperature change implemented by the program. To cancel this function, press the button( ; the symbol will disappearr from the display.Antifreeze temperature
U
In the event of an extended absence, you can activate the anti-freeze temperature mode. This prevents the unpleasant consequences of water freezing in the heating system by automatically setting the temperature to 7°C. To set the anti-freeze program, simply select program 0 on the desired day of the week.
Description of AURATON Fornax
heating or air conditioning device controller (wireless receiver)
The AURATON Fornax (wireless receiver) works with the AURATON Libra RH wireless controller (transmitter). The AURATON Fornax is mounted on a heating or air conditioning device and can operate under loads up to 16A/10A .

- Detachable 230V AC power connector terminals
- Mounting hole
- Power button
- Power LED
- Unpaired devices unpairing button
- Diode indicating that the actuator is switched on
- LED indicating that the actuator is turned off
- Device pairing button for AURATON Fornax
- Detachable terminals (voltage-free contacts COM–NC, COM–NO)
Legend – description of the diode signaling
D G The diode is green – the actuator is turned off (COM and NC contacts closed). E I The diode lights red – the actuator is switched on (COM and NO contacts closed). D H The diode flashes green – the AURATON Fornax receiver is waiting for the device to be paired – chapter: "Pairing the AURATON Libra RH wireless regulator (transmitter) with the AURATON Fornax – wireless controller of a heating or air-conditioning device (wireless receiver)". E J The diode flashes red – the AURATON Fornax receiver is waiting for the previously paired device to be unpaired – chapter: "Unpairing the regulator from AURATON Fornax – wireless controller of a heating or air-conditioning device (wireless receiver)". K The LED flashes alternately red and green:
ALARM – the AURATON Fornax receiver has lost connection with the paired device – chapter: "Special situations"
RESET – the AURATON Fornax receiver.
Removing all devices paired with the AURATON Fornax receiver – heating device controllerF Green power LED – AURATON Fornax receiver turned on. Connecting the AURATON Fornax cables
PATTENTION!
Q
The cables supplied with the AURATON Libra H SET are designed to carry a maximum load of 2.5 A.
If you connect devices with higher power, replace them with cables of appropriate cross-section.
Do not use twisted pair cables or teletechnical cables.NOTE:
The power supply should be turned off when installing the AURATON Fornax receiver. It is recommended that the AURATON Fornax be installed by a specialist.NOTE:
The building's permanent installation must include a circuit breaker and overcurrent protection.NOTE:
For ease of installation, the connectors are equipped with removable terminals. Before making cable connections, they can be disconnected from the AURATON Fornax. Cables can be routed through the bottom of the AURATON Fornax by breaking out the holes in the mounting plug, or through the back of the AURATON Fornax if the cables are led out of the wall. To connect from the back, break out the plug.
- mounting plug
Remove the front cover of the AURATON Fornax by unscrewing the screws halfway.

Connect the heating device to the AURATON Fornax receiver's control connector terminals. Follow the heating device's service manual. The most commonly used terminals are COM (common) and NO (normally open).

Connect the power cables to the power connector terminals of the AURATON Fornax receiver while observing safety rules.

- Cable mounting bracket.
After connecting the cables, secure them with the "cable retaining clip" and re-screw the cover to the AURATON Fornax receiver.
Mounting the AURATON Fornax – wireless controller of a heating or air conditioning device (wireless receiver) to the wall
To attach the AURATON Fornax receiver to the wall:
- Remove the front cover of the receiver, see the section "Connecting the AURATON Fornax cables" .
- Mark the position of the mounting screw holes on the wall.
- In the marked places, drill holes with the diameter of the dowels included in the kit (5 mm).
- Insert expansion bolts into the drilled holes.
- Screw the AURATON Fornax receiver to the wall with screws so that they hold the device securely.
NOTE:
If the wall is wooden, there is no need to use expansion bolts. Drill 2.7mm holes instead of 5mm and drive the screws directly into the wood.NOTE:
Do not place the AURATON Fornax receiver in metal housings (e.g. mounting box, metal furnace housing) so as not to interfere with the operation of the AURATON Libra RH.Pairing the AURATON Libra RH weekly wireless temperature controller (transmitter) with the AURATON Fornax heating or air conditioning device controller (wireless receiver)
After connecting to the mains, turn on the receiver by briefly pressing the power button ( F ). When the device is turned on, the green power LED will illuminate and a single beep will sound. To turn off the AURATON Fornax, e.g., outside the heating season, hold the power button for 3 seconds until you hear a double beep and the green power LED turns off, turning off the heating device.
NOTE:
The AURATON Libra RH wireless thermostat (transmitter) sold together with the AURATON Fornax – wireless heating or air conditioning device controller (wireless receiver) in the AURATON Libra H SET is already paired. Devices purchased separately require "pairing."- Pairing the AURATON Libra RH (transmitter) with the AURATON Fornax is initiated by pressing the right pairing button ( D ) – a single beep on the AURATON Fornax receiver – and holding it for at least 3 seconds until the LED starts flashing green (double beep), then releasing the button.
The AURATON Fornax receiver waits 120 seconds for pairing. After this time, it will automatically return to normal operation. - On the AURATON Libra RH (transmitter), press the buttonh for 5 seconds until the transmitting symbol ( = ) lights up on the display. Release the button – the AURATON Libra RH transmits a pairing signal for 5 seconds.
- Successful completion of pairing is indicated by the LED on the AURATON Fornax receiver stopping flashing green, by a single sound signal and by the receiver switching to normal operation.
If an error occurs during pairing, repeat steps 1 and 2. In case of subsequent errors, unpair the device by RESETting the AURATON Fornax receiver, see "RESET - Unpairing the device from the AURATON Fornax - wireless controller of a heating or air-conditioning device (wireless receiver)" and try pairing the devices again.
NOTE:
The AURATON Fornax receiver can only be paired with one AURATON Libra RH.Signaling of operation and receipt of data packets
Each time a radio transmission is received from a paired device, the AURATON Fornax receiver signals this with a momentary alternating color change of the LEDs. When the relay is turned on, the LED is red; when the relay is turned off, the LED is green.
NOTE:
Pressing any button is signaled by a short beep.Writing off AURATON Libra RH – a weekly, wireless temperature controller from AURATON Fornax
- Unlinking the AURATON Libra RH (transmitter) from the AURATON Fornax receiver is initiated by pressing the left unlink button ( E ) on the receiver for at least 3 seconds until the LED flashes red, then releasing the button. The sound signal works in the same way as pairing, i.e., pressing the button is signaled by a short beep, followed by a double short beep after 3 seconds.
The AURATON Fornax receiver waits 120 seconds for the device to be unlinked. After this time, it will automatically return to normal operation. - On the AURATON Libra RH (transmitter), press the buttonh for 5 seconds until the transmitting symbol ( = ) lights up on the display. Release the button.
- Successful completion of the write-back is indicated by the LED on the AURATON Fornax receiver stopping flashing red, a single sound signal and the receiver switching to normal operation.
If an error occurs during unsubscribing, repeat steps 1 and 2. In case of subsequent errors, unsubscribe the paired device, see "RESET – Unsubscribing a device paired to AURATON Fornax – wireless controller of a heating or air-conditioning device (wireless receiver)" .
RESET – Unpairing a device paired with AURATON Fornax – wireless controller of a heating or air conditioning device (wireless receiver)
To unpair a paired device (e.g., AURATON Libra RH) from AURATON Fornax, simultaneously press and hold both the pairing and unpairing buttons ( D and E ) for at least 5 seconds until the LED indicator changes to alternating green and red flashing. Then release both buttons. Audible signal: pressing the button – a short beep – after 5 seconds – a double short beep.
Successful unpairing is indicated after approximately 2 seconds by the indicator changing to green and then briefly fading.NOTE:
If you disconnect the AURATON Fornax receiver from the power supply after a RESET and then reconnect it, the receiver will automatically enter "pairing" mode for 120 seconds. A newly purchased AURATON Fornax receiver (not included with the AURATON Libra RH) that does not have factory-paired devices will behave identically.RESET AURATON Libra RH
Reset is performed by removing the battery until the data disappears from the display.
MASTER RESET AURATON Libra RH
MASTER RESET is performed by pressing and holding the button( while inserting the batteries. This returns the AURATON Libra RH to its factory settings.
NOTE:
All user programs are deleted!Configuration settings
Configuration settings are made sequentially:
heating mode/
air conditioning mode
hysteresis change
offset change
clock calibration
setting the SE lock code
(hotel mode)To enter the configuration settings change mode, hold down theh and( for 3 seconds until the settings menu is displayed.
Heating mode/Air conditioning mode
AURATON Libra RH can operate in two modes:

Heating mode (factory set) – set it when AURATON Libra RH is to cooperate with heating devices. 
Air conditioning mode – set it when AURATON Libra RH is to cooperate with air conditioning devices. Turn the knob left or right to set the desired mode. Confirm your selection by pressing the button( . AURATON Libra RH will move on to the next parameter.
Hysteresis change
Hysteresis is designed to prevent the actuator from switching on too frequently due to minor temperature fluctuations.
For example, for HI 2 hysteresis, with the temperature set to 20°C, the boiler will turn on at 19.8°C and turn off at 20.2°C. For HI 4 hysteresis, with the temperature set to 20°C, the boiler will turn on at 19.6°C and turn off at 20.4°C.
The hysteresis change mode is indicated by the flashing HI sign. Turn the knob left or right to set the desired hysteresis.
HI 2 – ±0.2 °C (factory setting),
HI 4 – ±0.4 °C,
HI P – PWM operating mode (section “PWM operating mode”).
Confirm the selection by pressing the button( . AURATON Libra RH will move on to changing the next parameter.Offset change
Offset allows you to calibrate temperature readings with a tolerance of ±3°C. For example, the AURATON Libra RH indicates that the room temperature is 23°C, while a standard room thermometer hanging next to it reads 24°C. By changing the offset by +1 degree, the AURATON Libra RH will display the same temperature as the room thermometer.
Offset change mode is indicated by the flashing OFFS sign. Turn the knob left or right to set the desired value within the range of -3.0 to 3.0 (factory setting – 0.0). Confirm your selection by pressing the button( . AURATON Libra RH will move on to the next parameter.
NOTE:
If you do not press any button for 10 seconds while changing the configuration settings, AURATON Libra RH will return to normal operating mode.NOTE:
The first press of any function button always turns on the backlight, and only the next press activates the button function.Clock calibration
This function is used to correct the clock readings if they deviate. If you notice the clock is malfunctioning over the course of a week, determine the error rate. This value should be entered in the AURATON Libra RH in seconds. Confirm your selection by pressing the OK button. The AURATON Libra RH will move on to the next parameter.
Example 1:
After a week of operation, the AURATON Libra RH displays the time faster by 1 minute and 20 seconds (60 + 20 = 80). In this case, slow down the clock by setting C -80.Example 2:
After a week of operation, the AURATON Libra RH shows the time slowed down by 2 minutes (2 x 60 = 120). In this case, the clock should be advanced by setting C 120.NOTE:
For the clock calibration function to work correctly, the number of seconds must be determined after a week of operation of the AURATON Libra RH (7 days = number of seconds to be added or subtracted, maximum 294 seconds).NOTE:
If you do not press any button for 10 seconds while changing the configuration settings, AURATON Libra RH will return to normal operating mode.Setting the SE lock code
(hotel mode)
NOTE:
Before setting the code, you must program the controller according to your needs. Once the code is locked, this will not be possible.This function allows you to lock the buttons against unauthorized access by third parties (hotel mode).
To enter the configuration settings change mode, hold down theh and( for 3 seconds until the settings menu is displayed.
Press the button( repeatedly until the display shows ) in place of the temperature and four dashes in place of the time. The first dash will flash (edit mode) and if no change is made within 10 seconds or the button is pressed without changing the value,( the AURATON Libra RH will return to normal operation (the lock function will be disabled - factory setting).

If the +/- knob changes the value from 0 to 9 within 10 seconds, press the button within the next 10 seconds( . Failure to do so will result in the AURATON Libra RH exiting this mode (normal operation) and the setting procedure having to be restarted.
However, if the button is pressed within 10 seconds after setting the first digit,( the AURATON Libra RH will proceed to editing the next digit (the second).
After setting the last, fourth digit, press the button within 10 seconds( , and the code value will be saved. Failure to press the button( will result in the value not being saved (no lock) and the AURATON Libra RH will return to normal operation.Once the button lock is set, AURATON Libra RH displays all the necessary information.
NOTE:
The code is set only once and is remembered by AURATON Libra RH even after replacing the batteries.The first time you press any button, only the backlight turns on.
When hotel mode is enabled, you cannot edit programs, set the time, change the operating mode ( S , T ), or access the menu.Temperature and duration editing function (hotel mode enabled)
the buttonn allows you to edit the temperature within the range from the day temperature (S ) to the night temperature ( T ), and only within that range. The temperature value then flashes for 10 seconds. Adjust the value using the +/- knob and press the button to confirm( (not pressing the button( will not save the setting).
After pressing the button,( you can edit the time period for which the manual temperature will apply (from 1 hour to 24 hours is visible on the right). Change the time using the +/- knob and press the button to confirm( .In manual mode, the display will show the temperature and the time remaining until the end of the program. After this time, the AURATON Libra RH returns to normal operation (set program).
If you need to cancel this setting before it automatically ends, use the buttonh .
Turning off hotel mode
After pressing and holding the button for 5 seconds,( the display will show the inscription ) and the hour will be replaced by a dash with the first one flashing for editing.

Use the +/- knob to select the set code. After each digit, press( (within 10 seconds), otherwise the AURATON Libra RH will return to normal operation (lock enabled). After entering the correct code, the AURATON Libra RH will resume normal operation (lock disabled).
handr buttons simultaneously for 5 seconds . Activation of the lock is signaled by the message ) , which will be visible on the display for 3 seconds.NOTE:
The lock function using theh andr is not active if the lock code is not set.PWM operating mode
(Pulse-Width Modulation)
By changing the hysteresis settings (see the "Configuration Settings" section), you can enable PWM operation. In this mode, the AURATON Libra RH periodically switches on the heating device to minimize temperature fluctuations. The AURATON Libra RH checks the temperature rise and fall times.
Knowing these values, AURATON Libra RH turns the heating device on and off in cycles to keep the temperature as close to the set point as possible.

- Temperature
- Time
- Set temperature
- Room temperature
NOTE:
In PWM mode, the AURATON Libra RH may turn on the heating device even if the room temperature is higher than the setpoint temperature. This is due to the PWM algorithm, which aims to maintain the setpoint temperature and anticipate the heating system's behavior.Special situations
- If we lose three consecutive transmissions (after 15 minutes) from the AURATON Libra RH (transmitter), a failure will be signaled on the AURATON Fornax receiver (the LED will continuously flash alternately red and green). Until the problem is resolved, the receiver will revert to the memorized on/off cycle from the last 24 hours.
- When the signal from AURATON Libra RH returns, the error is cleared and the AURATON Fornax receiver switches to normal operation.
Additional notes
- AURATON Libra RH (transmitter) must be installed at least 1 meter from the receiver (too strong a signal from the transmitter may cause interference).
- Data is transmitted from the AURATON Libra RH (transmitter) to the AURATON Fornax receiver whenever the ambient temperature changes by 0.2°C. If the temperature does not change, the AURATON Libra RH transmits control data every 5 minutes (this is manifested by a momentary alternating change in the LED color).
- In the event of a power outage, the AURATON Fornax receiver will turn off. When power is restored, the heating device will automatically turn on, and the AURATON Fornax receiver will wait for a signal from the paired AURATON Libra RH (transmitter) for a maximum of 5 minutes after power is restored. Once the signal is received, the AURATON Fornax receiver will resume normal operation.
- Placing the AURATON Fornax receiver in a metal housing (e.g. mounting box, metal furnace housing) will interfere with the operation of the AURATON Libra RH.
- In AURATON Libra RH (transmitter) you can turn the control functions on or off at any time (e.g. after the heating season) by briefly (approx. 5 seconds) holding the button( (AURATON Libra RH will only show the current time and room temperature – no "timeline").
- The first press of any function button always turns on the backlight, and only the next press activates the key's function. When using the knob, each step keeps the backlight on.
- When programming any function, not pressing any button for 10 seconds is equivalent to pressing the button. (.
AURATON Fornax connection diagram

- Control
- A heating device , e.g. a gas furnace
- Electric heating or air conditioning device (MAX 230 V AC, 16 A)
Cleaning and maintenance
- Clean the exterior of the device with a dry cloth. Do not use solvents (such as benzene, thinner, or alcohol).
- Do not touch the device with wet hands. This may result in electric shock or serious damage to the device.
- Do not expose the device to excessive smoke or dust.
- Do not touch the screen with a sharp object.
- Avoid contact of the device with liquids or moisture.
Technical data
Operating temperature range: 0 – 45°C Range of action: in a typical building, with standard wall construction – approx. 30 m;
in open areas – up to 300 mRadio frequency: 868.850 MHz
869.000 MHzRadio signal strength: Up to 11 dBm Degree of protection: IP20 AURATON Libra RH:
Power supply: 2 x AAA (2 x 1.5 V), alkaline Number of temperature levels: 2 Antifreeze temperature: 7°C Temperature control range: 5 – 30°C (measurement error +/- 1°C) Hysteresis: ±0.2°C / ±0.4°C / PWM Operating status indication: LCD display Dimensions [mm]: 90 x 90 x 36 AURATON Fornax:
Power supply: 230V AC, 50Hz, 1.5W Operating status indication: LED diodes, sound Relay load capacity: Max. 250 V AC, max. 16 A Receiver category: 2 Suggested mounting location: Near a heating or air conditioning unit Dimensions [mm]: 100 x 100 x 29 Disposal of the device
O
Devices are marked with a crossed-out waste bin symbol. In accordance with European Directive 2012/19/EU and the Waste Electrical and Electronic Equipment Act, this marking indicates that this equipment, after its useful life, must not be disposed of with other household waste.
Users are obligated to dispose of it at a collection point for used electrical and electronic equipment.LARS Andrzej Szymański hereby declares that the radio equipment type AURATON Libra H SET is in compliance with Directive 2014/53/EU and 2011/65/EU. The full text of the EU declaration of conformity is available in the download section below.
Manufacturer's address and contact details:
LARS, ul. Świerkowa 14
64-320 Niepruszewo
www.auraton.pl