AURATON Switch TWO – SUPLA


Fig. 6. Time graphs defining the LED lighting pattern during software update:

  1. Condition: Device in OTA update mode.
    Diode:
  2. Condition: Restoring a previous version of the software.
    Diode:
  3. Condition: Uploading software
    (continuous diode status until upload is completed)
    Diode:
  4. Condition: No software to load (2 blinks).
    Diode:
  5. Condition: Software loaded correctly (3 flashes).
    Diode:
  6. Condition: Software failed to load, incorrect version in memory or memory communication problem (3 flashes).
    Diode:
  7. Condition: An unexpected error occurred during a software update, which prevents the device from turning on correctly.
    Contact with service required.
    Diode:

Restoring a previous software version

After completing the update, or if it fails (Fig. 6.4), you can roll back to the previous software version. There are two ways to do this.

With power disconnection

After pressing the button on the device's housing, turn on the power – the LED will flash as shown in Fig. 6.2. While still holding the button, wait until the LED stops flashing. The next steps are the same as for updating the software.

Without disconnecting the power supply

If the device starts correctly and responds to the button according to basic functions, such as pairing and deletion, you can restore the previous version without unplugging the device. Hold the button for at least 7 seconds until the LED turns orange, then release it. Then, while the LED remains lit, hold the button again and proceed as in the example with disconnecting the power supply.


Technical data

AC supply voltage: 60-240V AC, 50-60Hz
DC supply voltage: 12-30V DC
Maximum power consumption: ≤1 W
Power consumption in standby mode: ≤0.4 W
Operating temperature: 0-35°C
Dimensions: 48 x 35 x 19 mm
Power cord type, maximum permissible power cord cross-section. 3 x 2.5 mm2
Permissible load: up to 4.3A (<1kW) per channel for resistive load
Security type: An external circuit breaker with a maximum current of 10A is required.
Control element: Electromagnetic relay with micro-break
Control method: remotely – by radio,
locally – using buttons
Maximum number of paired devices: 1
Cooperation with the internet gateway AURATON Box
Degree of protection IP20
Radio signal strength: up to 11 dBm
Radio receiver category: 2
Radio protocol: AURA
Radio operating frequency: 868.150 MHz
868.450 MHz
Reception: up to 300 m in open space
up to 30 m in a building, depending on obstacles

Disposal of the device

O

Devices are marked with a crossed-out waste bin symbol. In accordance with European Directive 2012/19/EU and the Waste Electrical and Electronic Equipment Act, this marking indicates that this equipment, after its useful life, must not be disposed of with other household waste.
Users are obligated to dispose of it at a collection point for used electrical and electronic equipment.

LARS Andrzej Szymański hereby declares that the AURATON Switch TWO radio equipment type complies with Directives 2014/53/EU and 2011/65/EU. The full text of the EU declaration of conformity is available in the download section below.


Manufacturer's address and contact details:
LARS, ul. Świerkowa 14
64-320 Niepruszewo
www.auraton.pl


Downloads

User manual ver. 20250701
This document collects information on the safety, installation and use of the AURATON Switch TWO device.


Safety information

P

Installation should be performed by qualified electricians, in accordance with national installation regulations. Before installing the device, please read this manual thoroughly. For safety reasons, do not install the device without a housing or with a damaged housing, as this poses a risk of electric shock.

Q

CAUTION!
Before starting installation, make sure that no dangerous voltage is present on the connecting cables.


Device description

The AURATON Switch TWO is used to control electrical devices using buttons connected to inputs I1 and I2 (Fig. 1) or remotely. The device supports both bistable and monostable (bell) buttons, with no additional settings required. Changing the button's state changes the state of the corresponding relay, transmitting or cutting voltage from outputs O1 and O2, as shown in the diagram in Fig. 3. The device measures the mains voltage and receiver parameters such as active power and total energy consumption. The device is equipped with a LED indicating the current operating status and a button for adding or removing a device from the Supla system (Fig. 1). The AURATON Switch TWO module is intended for indoor use only, for installation in junction boxes.

Fig. 1. Device diagram

1 – Connection terminals
2 – Indicator light
3 – Pairing/deleting device from the system button

Fig. 2. Dimensions of the device


Device functions

The device was designed and manufactured in Poland in accordance with applicable standards. It is suitable for installation in junction boxes with a minimum depth of 60 mm and meeting national standards.

A correctly connected and configured device allows you to:

  • Independent control of two receivers.
  • Possibility to control conventional and LED lighting.
  • Can be controlled using monostable, bistable or remote buttons.
  • Measuring the supply voltage value.
  • Measurement of active power and total energy consumption of the connected receiver.
  • Secure radio connection using the AURA protocol.

Additionally, the AURATON Switch TWO is equipped with:

  • Software protection against switching on the voltage when it is not within the permissible operating range of the device.
  • Software overcurrent protection to protect the module from damage.
  • Software protection against exceeding the permissible internal temperature.
  • Two-color internal LED to identify device status.

Description of measured parameters:

Active power – the power consumed by a device, resulting from the supply voltage, current, and load characteristics. This value directly translates into electricity bills.

Electricity consumption – a measure of electricity consumption, expressed in kWh (kilowatt-hours). This value is also displayed on the electricity meter installed in every home.


Connection to the power supply

AURATON Switch TWO can be connected to a 230 V AC mains supply or to a 12-30 V DC source. The electrical installation should be protected by a circuit breaker with a maximum current of 10 A, meeting national standards. The minimum cross-section of the connecting wires should be 1 mm2 , while the maximum cross-section of the connecting wires cannot exceed 2.5 mm2 . No additional settings are required for either type of supply voltage. The connection method is shown in Fig. 3. Pay particular attention to the marking of the power supply terminals N/+, L/-.

Q

WARNING!
Improper connection of the device may result in damage to the device and pose a risk of electric shock.

Fig. 3. How to connect power to the AURATON Switch TWO module:

Direct voltage 12-30 V DC:

Alternating voltage 60-240 V AC:

 

Explanations for the diagram:

  1. (N/+) neutral terminal or (+) for a DC voltage source
  2. (L/-) phase terminal or (-) for a DC voltage source
  3. (O1) receiver output terminal 1
  4. (O2) receiver output terminal 2
  5. (l1) switch terminal for receiver 1
  6. (l2) switch terminal for receiver 2
  7. – receivers
  8. – wall switch

Device pairing

Once the module is properly connected and powered on, the LED inside the housing should begin flashing red, as shown in Fig. 5.1. This indicates that the device is not paired with the SUPLA system. If the LED flashes as shown in Fig. 5.3 or Fig. 5.4, the device must first be removed from the system.

Enabling pairing – AURATON Switch TWO

To activate pairing, hold down the button on the device's housing. Release the button when the LED lights green. The pairing process should begin, and the LED should flash as shown in Figure 5.2. During this time (approx. 30 seconds), initiate pairing on the other device you want to pair with the AURATON Switch Two.

Enabling pairing – Auraton Box gateway

Pairing the AURATON Switch TWO two-channel switch with the AURATON Box gateway can be done in two ways:

  • On the AURATON Box gateway, briefly press the right "Auraton" pairing button ( ) – the LED under the button will start flashing. Then, put the single-channel switch into pairing mode.

or

  • In Supla Cloud, enter the AURATON Box gateway channel and press the "Pair new devices or sensors" button – the LED under the right "Auraton" pairing button will start flashing. Then, put the dual-channel switch into pairing mode.

After pairing the AURATON Switch TWO with the Auraton Box gateway, it is recommended to immediately name all of its channels (2x "Relay" channels and 2x "Electricity Meter" channels) in Supla Cloud. By default, the device is named according to its model or intended use, e.g., "Switch TWO 01," which can be confusing when using multiple devices of the same type. To facilitate identification, it is a good idea to give the device a unique name immediately after pairing. To do this, edit the "Channel Name" and confirm the changes by clicking " Save Changes ."

Fig. 4. Adding a device to the Auraton Box gateway

                                 

Fig. 5. Time graphs defining how the LED lights up when the device is paired:

  1. Condition: The device is not connected to the system.
    Diode:
  2. Condition: Device in pairing mode
    Diode:
  3. Condition: The device is connected to the system and is working properly.
    Diode:
  4. Condition: The device cannot connect to the Auraton system – check the range.
    Diode:

Factory reset

To restore the factory settings, hold the button during normal operation (approx. 5 seconds) until the LED lights red. Release the button and press it again within 3 seconds to confirm the operation. All information on the device will be cleared. The LED should indicate that it is not connected to the AURATON Box gateway (Fig. 5.1).


Local control

Once the device is properly connected to the power supply (Fig. 3), local load control is possible using switches connected to inputs I1 or I2 . Standard flush-mounted or surface-mounted switches, both bistable (with voltage retention) and monostable (bell) types, can be used. Once connected, no additional configuration is required due to the type of switch included.


Control via the SUPLA application

After successfully adding AURATON Switch TWO to the SUPLA system, the device is visible in the application as two channels (in the figure below: "Light switch – kitchen 1" and "Light switch – kitchen 2"):

After accessing any of the AURATON Switch TWO channels in the SUPLA app, the user has access to three main tabs: General , History , and Settings . Each tab provides different information and control functions.

General tab displays basic device operating parameters in real time. Here you can check:

  • Active energy consumed (meter reading) – total amount of energy consumed since the device was installed (kWh).

  • Active energy consumed (current month) – energy consumed by the device in the current calendar month (kWh).

  • Voltage – current voltage in the network (V).

  • Current – ​​the current flowing through the device (A).

  • Active power – current power consumed by the device (W).

  • Power factor – information about the quality of the power consumed (cos φ).

  • Active Consumption – alternative view of current energy consumption (kWh).

At the bottom of the tab there are two buttons for manual control of the device:

  • Turn on – turns on the device connected to the relay.

  • Turn Off – Turns off the connected device.

History tab allows you to track your electricity consumption over a selected time period. Available options include:

  • Range – allows you to select the analyzed time period (e.g. last 7 days).

  • Data type – allows you to select data aggregation (e.g. days, weeks).

The bar chart presents energy consumption for a given period – by default in kilowatt-hours [kWh].

In the Settings , users can customize how data for this channel is displayed. The following options are available:

  • Value shown in channel list – allows you to choose which value will be visible in the main channel preview. Options include:

    • Active energy consumed,

    • Active power,

    • Tension.

The above information helps the user monitor energy consumption, optimize the operation of devices and control them locally or remotely in a simple and intuitive way.

Device configuration in SUPLA Cloud

Switch channel

After logging in to the SUPLA Cloud platform and going to one of the switch channels of the AURATON Switch TWO device, the user gains access to detailed switch settings.

  • Channel Name – The assigned channel name is displayed at the top of the screen, e.g., "Light Switch – Kitchen 1." This name can be freely edited to make it easier to identify the device.

  • Device ID and channel number – below the name there is information about the relay number (ID: 16883) and channel number (e.g. 28), which makes it easier to identify the equipment in the system.

  • Function – The “Function” section displays the currently assigned function of the channel (e.g., “Light Switch”). If necessary, the user can change it by clicking the “Change Function” button.

  • Show on Client Devices – This option lets you decide whether the feed is visible to other users with access to this location. Enabling this feature (green slider) will make the feed appear in their apps.

  • Associated Measuring Channel – This section allows you to associate the control channel with the measuring channel used to read energy consumption. For example, the Switch TWO 01 ID16884 channel acts as the electricity meter assigned to this switch.

  • Integration Settings Amazon Alexa and Google Home are available . Click the appropriate button to add the device to your chosen smart home ecosystem.

This view enables comprehensive configuration of the switch and its integration with other services in the SUPLA system.

Channel configuration "Electricity meter"

After going to the “Electricity Meter” in SUPLA Cloud, the user can configure its operation according to their own needs.

The page layout is as follows:

  • At the top left of the screen, you will see the channel name .

  • On the right side there is a "Delete" that allows you to permanently remove the device from the SUPLA system.

Configuration settings

Below are the channel configuration options:

  1. Function – allows you to specify the type of channel operation.

  2. Channel Name – allows you to change the name assigned to a given counter.

  3. Show on Client Devices – a slider that determines whether the channel will be visible in mobile apps and user interfaces.

  4. Active phases – number of active phases (in the case of AURATON Switch TWO devices this value is always 1 ).

  5. Associated Control Channel – allows you to specify a channel that is to be logically associated with this counter.

"Costs" tab

After clicking on the "Costs" , fields expand allowing you to assign price parameters:

  • Price per kWh – enter the cost of one kilowatt-hour of electricity.

  • Currency – specify the currency unit (e.g. PLN, EUR).

"History" tab

Clicking the "History" reveals settings related to data archiving:

  • Store voltage history – allows you to save voltage history.

  • Store Current History – allows you to save current history.

  • Store active power history – allows you to record the history of power consumption.

Recommendation: To save disk space on your server, it is recommended to leave these three sliders disabled unless detailed data analysis is necessary.

  • Added Value – allows you to assign an additional value to the Active Energy Consumed measurement. After clicking the "Set Added Value" , you can enter its numerical value.

                                 

"Voltage Monitoring" tab

Clicking on the "Voltage Monitoring" expands the options for monitoring the voltage values:

  • Enabled – activating this option allows you to specify warning thresholds:

    • Low voltage threshold – value in [V] below which a voltage drop will be reported.

    • High voltage threshold – value in [V] above which a voltage increase will be reported.

Additional options

  • Reset counter – button to reset the energy counter.

Saving changes

After making any changes to the settings, press the "Save changes" to confirm and apply the new settings.


Software update

The AURATON Switch TWO two-channel switch has an automatic software update function.

If a new version is available, the update begins automatically – approximately 15 minutes after the last device is paired with the AURATON Box . This process runs in the background and requires no additional user action.

This ensures that the device always benefits from the latest improvements and fixes introduced by the manufacturer.


Fig. 6. Time graphs defining the LED lighting pattern during software update:

  1. Condition: Device in OTA update mode.
    Diode:
  2. Condition: Restoring a previous version of the software.
    Diode:
  3. Condition: Uploading software
    (continuous diode status until upload is completed)
    Diode:
  4. Condition: No software to load (2 blinks).
    Diode:
  5. Condition: Software loaded correctly (3 flashes).
    Diode:
  6. Condition: Software failed to load, incorrect version in memory or memory communication problem (3 flashes).
    Diode:
  7. Condition: An unexpected error occurred during a software update, which prevents the device from turning on correctly.
    Contact with service required.
    Diode:

Restoring a previous software version

After completing the update, or if it fails (Fig. 6.4), you can roll back to the previous software version. There are two ways to do this.

With power disconnection

After pressing the button on the device's housing, turn on the power – the LED will flash as shown in Fig. 6.2. While still holding the button, wait until the LED stops flashing. The next steps are the same as for updating the software.

Without disconnecting the power supply

If the device starts correctly and responds to the button according to basic functions, such as pairing and deletion, you can restore the previous version without unplugging the device. Hold the button for at least 7 seconds until the LED turns orange, then release it. Then, while the LED remains lit, hold the button again and proceed as in the example with disconnecting the power supply.


Technical data

AC supply voltage: 60-240V AC, 50-60Hz
DC supply voltage: 12-30V DC
Maximum power consumption: ≤1 W
Power consumption in standby mode: ≤0.4 W
Operating temperature: 0-35°C
Dimensions: 48 x 35 x 19 mm
Power cord type, maximum permissible power cord cross-section. 3 x 2.5 mm2
Permissible load: up to 4.3A (<1kW) per channel for resistive load
Security type: An external circuit breaker with a maximum current of 10A is required.
Control element: Electromagnetic relay with micro-break
Control method: remotely – by radio,
locally – using buttons
Maximum number of paired devices: 1
Cooperation with the internet gateway AURATON Box
Degree of protection IP20
Radio signal strength: up to 11 dBm
Radio receiver category: 2
Radio protocol: AURA
Radio operating frequency: 868.150 MHz
868.450 MHz
Reception: up to 300 m in open space
up to 30 m in a building, depending on obstacles

Disposal of the device

O

Devices are marked with a crossed-out waste bin symbol. In accordance with European Directive 2012/19/EU and the Waste Electrical and Electronic Equipment Act, this marking indicates that this equipment, after its useful life, must not be disposed of with other household waste.
Users are obligated to dispose of it at a collection point for used electrical and electronic equipment.

LARS Andrzej Szymański hereby declares that the AURATON Switch TWO radio equipment type complies with Directives 2014/53/EU and 2011/65/EU. The full text of the EU declaration of conformity is available in the download section below.


Manufacturer's address and contact details:
LARS, ul. Świerkowa 14
64-320 Niepruszewo
www.auraton.pl


Downloads